Heating Hood
The VMP AirFlow features a circulating air heating hood mounted above the membrane frame.
The fully insulated hood and the air guidance system with multiple fans ensure optimal heat distribution.
Chassis
The standard chassis allows flexible use of the machine throughout the entire facility.
Control System
Our vacuum presses with heating are equipped as standard with a Siemens PLC.
This controls the vacuum pump as well as the heating and ventilation elements and enables, for example, programming of heating curves and a data logger function.
Vacuum Pump & Vacuum Tank
This model is equipped with a powerful oil-lubricated vacuum pump (40 m³/h) and a 270-liter vacuum tank.
This enables a pressing pressure of up to 10 t/m².
Vacuum Press with Heating HoodVMP AirFlow Professional / Industrial
The Most Important Advantages at a Glance:
- Excellent & Uniform Heat Distribution
- Welded Frame Construction for Maximum Stability
- Oil-Lubricated Vacuum Pump with 40 m³/h for Shorter Pressing Times
- PLC Control for High Operating Comfort
- Fast Evacuation Through the 270-Liter Vacuum Tank
- High Flexibility Through the Smooth-Running Chassis
- Custom Sizes Available
With a temperature of up to 100°C in the Professional model version and 160°C as Industrial, the VMP AirFlow impresses not only with its outstanding heat distribution, but also with a heating capacity of up to 18 kWh.
This gives you the ability to activate adhesives and make materials more pliable. Particularly in the automotive industry, corresponding adhesives are used when covering dashboards and interior panels with leather.
The welded frame construction also ensures maximum stability.
The standard oil-lubricated vacuum pump provides pressure of up to 10 t/m², generating a vacuum of up to 99.9%.
Supported by a 270-liter vacuum tank, you evacuate the pressing chamber in record time.
In terms of comfort, the VMP AirFlow is distinguished by a standard PLC control with touchscreen operation, which offers both a manual operating mode and an automatic mode with selection of various programs.
As an optional feature, our PLC has a data logger for vacuum and temperature to meet the requirements of demanding processes.
Technical Data of the Vacuum Press
Pressing Surfaces
Pressing lengths: 2500, 3000, 3500, 4000 mm
Pressing depths: 1420 mm
additional pressing surfaces available upon request
Standard Equipment
Heating hood: Professional up to 100°C
Membrane: 2 mm silicone
Control system: Siemens PLC control
Vacuum pump: 40 m³/h oil-lubricated
max. vacuum: 99.9%
Vacuum tank: 270 liters
additional vacuum connection
chassis
Model Variants
Heating hood: Professional up to 100°C or Industrial up to 160°C
as auxiliary table without vacuum pump and vacuum tank
custom sizes
Electrical
Connected load: 11 to 40 kW (size-dependent)
Voltage: 400 V / 50 Hz
Options
data logger for vacuum & temperature
additional interchangeable membrane frame with 2 mm silicone membrane
UpRight opening and closing system